We select top off-the-shelf hardware to offer, in combination with our award-winning software, the best integrated solutions for vibration analysis, Operational Modal Analysis, and Structural Health Monitoring.

Our solutions are designed for specific applications and they are code compliant.

They are also customizable to a large extent, and ready for use thanks to their steep learning curve.Select the measurement equipment that most fits your needs among a number of options, or CONTATTI us if you need a tailored system.

starting-kit

laboratory

benchmark-bridge

benchmark-frame

Operational Modal Analysis of stiff structures or in very quiet environment - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_2

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-OMA.

    Recommended Software S2-OMA

    DEWESOFT 1

    Bundle: DEWESOFT_1

    • Distributed, EtherCAT synchronized measurement system.
    • Very low noise triaxial MEMS accelerometers: ±15 g full scale range.
    • Software: Dewesoft X, S2-OMA.

    Recommended Software S2-OMA

    SUNTA 2

    Bundle: SUNTA_2

    • Centralized, wired measurement system: 24 bit Delta-Sigma ADC, 1 kHz maximum sampling frequency.
    • Force balance accelerometers: userselectable full scale range.
    • Software: S2-OMA.

    Recommended Software S2-OMA

Modal based Structural Health Monitoring of stiff structures or in very quiet environment - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_2 (for indoor applications)

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-SHM

    Recommended Software S2-SHM

    DEWESOFT 1

    Bundle: DEWESOFT_1

    • Distributed, EtherCAT synchronized measurement system.
    • Very low noise triaxial MEMS accelerometers: ±15 g full scale range.
    • Software: Dewesoft X, S2-OMA.

    Recommended Software S2-SHM

Modal based Structural Health Monitoring (general purpose) - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_1

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT.

    Recommended Software S2-SHM

    NIPE 3

    Bundle: NIPE_3

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise miniature IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    DEWESOFT 1

    Bundle: DEWESOFT_1

    • Distributed, EtherCAT synchronized measurement system.
    • Very low noise triaxial MEMS accelerometers: ±15 g full scale range.
    • Software: Dewesoft X, S2-OMA.

    Recommended Software S2-SHM

Operational Modal Analysis (general purpose) - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_1

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT.

    Recommended Software S2-OMA

    NIPE 3

    Bundle: NIPE_3

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise miniature IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-OMA

Operational Modal Analysis of slender structures - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_1

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT.

    Recommended Software S2-OMA

    NIPE 2

    Bundle: NIPE_2

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-OMA

    DEWESOFT 1

    Bundle: DEWESOFT_2

    • Distributed, EtherCAT synchronized measurement system.
    • Triaxial MEMS accelerometers: ±2 g to ±8 g full scale range.
    • Software: Dewesoft X

    Recommended Software S2-OMA


Structural Health Monitoring of slender structures - Recommended bundle:
  • NIPE 2

    Bundle: NIPE_1

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT.

    Recommended Software S2-SHM

    NIPE 2

    Bundle: NIPE_2
    (for indoor applications)

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    DEWESOFT 1

    Bundle: DEWESOFT_2
    (with IP67 option for outdoor applications)

    • Distributed, EtherCAT synchronized measurement system.
    • Triaxial MEMS accelerometers: ±2 g to ±8 g full scale range.
    • Software: Dewesoft X

    Recommended Software S2-SHM

Seismic Structural Monitoring - Recommended bundle:
  • NIPE 5

    Bundle: NIPE_5

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low frequency, low noise IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    NIPE 6

    Bundle: NIPE_6
    (for indoor applications)

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low resolution IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    DEWESOFT 2

    Bundle: DEWESOFT_2
    (with IP67 option for outdoor applications)

    • Distributed, EtherCAT synchronized measurement system.
    • Triaxial MEMS accelerometers: ±2 g to ±8 g full scale range.
    • Software: Dewesoft X

    Recommended Software S2-SHM

Seismic and operational Structural Health Monitoring - Recommended bundle:
  • NIPE 5

    Bundle: NIPE_5

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low frequency, low noise IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    DEWESOFT 1

    Bundle: DEWESOFT_1
    (with IP67 option for outdoor applications)

    • Distributed, EtherCAT synchronized measurement system.
    • Very low noise triaxial MEMS accelerometers: ±15 g full scale range.
    • Software: Dewesoft X

    Recommended Software S2-SHM

Axial load indirect measure - Recommended bundle:
  • NIPE 3

    Bundle: NIPE_3
    (for tie-rods)

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise miniature IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-OMA

    NIPE 4

    Bundle: NIPE 4
    (for cables)

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Miniature IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-OMA


Axial load monitoring - Racommended bundle
  • NIPE 3

    Bundle: NIPE_3

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, very low noise miniature IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

    NIPE 4

    Bundle: NIPE 4

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Miniature IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT

    Recommended Software S2-SHM

Vibration measurements/monitoring (up to 1 kHz) - Recommended bundle:
  • DEWESOFT 2

    Bundle: DEWESOFT_2

    • Distributed, EtherCAT synchronized measurement system.
    • Triaxial MEMS accelerometers: ±2 g to ±8 g full scale range.
    • Software: Dewesoft X, S2-VIB.

    Recommended Software S2-VIB

    SUNTA 1

    Bundle: SUNTA 1

    • Centralized, wired measurement system: 24 bit Delta-Sigma ADC, 1 kHz maximum sampling frequency.
    • MEMS accelerometers: ±2 g full scale range.
    • Software: S2-VIB.

    Recommended Software S2-VIB


Vibration measurements/monitoring (low noise) - Recommended bundle:
  • NIPE 1

    Bundle: NIPE_1

    • Compact, centralized, wired measurement system: 24 bit Delta-Sigma ADC, 51.2 kHz maximum sampling frequency.
    • High sensitivity, low noise IEPE accelerometers: ±0.5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-VIB.

    Recommended Software S2-VIB

    DEWESOFT 1

    Bundle: DEWESOFT 1

    • Distributed, EtherCAT synchronized measurement system.
    • Very low noise triaxial MEMS accelerometers: ±15 g full scale range.
    • Software: Dewesoft X, S2-VIB.

    Recommended Software S2-VIB


Vibration measurements/monitoring in extended frequency range (up to 2 kHz) - Recommended bundle:
  • NIPE 6

    Bundle: NIPE_6

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low resolution IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-VIB.

    Recommended Software S2-VIB


Vibration measurements/monitoring (high amplitude vibrations) - Recommended bundle:
  • NIPE 4

    Bundle: NIPE_4

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Miniature IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-VIB.

    Recommended Software S2-VIB

    NIPE 5

    Bundle: NIPE_5

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low frequency, low noise IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-VIB.

    Recommended Software S2-VIB

    NIPE 6

    Bundle: NIPE_6

    • Compact, centralized, wired measurement system: 24 bit Delta- Sigma ADC, 51.2 kHz maximum sampling frequency.
    • Low resolution IEPE accelerometers: ±5 g full scale range.
    • Software: S2-DDA, S2-FFT, S2-VIB.

    Recommended Software S2-VIB

    DEWESOFT 3

    Bundle: DEWESOFT_3

    • Distributed, EtherCAT synchronized measurement system.
    • Triaxial MEMS accelerometers: ±10 g to ±40 g full scale range.
    • Software: Dewesoft X, S2-VIB.

    Recommended Software S2-VIB

vibration-amplitude

frequency-range

miniature

general-purpose

low-noise

uniaxial

triaxial

it_ITItalian
Newsletter Richiedi chiamata Contattaci